² 计量功效:撑持正(zheng)向(xiang)、反向(xiang)有(you)功电(dian)🗹能计量,此中(zhong)反向(xiang)电(dian)量计入正(zheng)向(xiang)电(dian)量;
² 费控形式转(zhuan)换(huan)功效:电能(neng)表备长途预(yu)支(zhi)费和(he)本地预(yu)支(zhi)费功效,两(liang)种形式能(neng)够按照办理须要随时转(zhua🐬n)换(hua🌜n);
² 充值功效:电(dian)表在本地预(yu)支费形式时(shi),用户必(bi)ꦛ须先充值后用电(dian),主动结算计费、扣(kou)费,无费断电(dian), 用户充值冲正余额(e)后电(dian)表主动合闸供电(dian);
² 退(tui)费功效:当用(yong)户搬(ban)迁时(shi),如电表(biao)内仍(reng)不足额(e)(e),能(neng)够将(jiang)预缴金额(e)(e)退(tui)还用(yong)户,而后将(jiang)电表(biao)余(yu)额(e)(e)主(zhu)动(dong)“归零”𝕴;
² 换表(biao)功效:当某一个电表(biao)产生毛病须(xu)要改换时,可共同体系完(wan)成换表ღ(biao)功效,记(ji)实(sღhi)旧表(biao)底数和新(xin)表(biao)底数并(bing)主动结(jie)算旧表(biao)数据和用度;
² 长途监控(kong)与通断(duan)电:能(neng)长途及时(shi)监测(ce)各装(zhuang)备(bei)的运转状态(tai), 长途节制通断(duan)电,可(ke)经(j🐬ing)由过程电脑下(xia)发号令对(dui)某一个(ge)或某一些房(fang)间(jian)停止(zhi)通断(duan)电节制。
² 恶性(xing)负载限定:电能表可主(zhu)动(dong)辨认(ren)恶性(xing♛)负载,呈现(xian)恶性(xing)负载(大功率用电装备)后(hou)主(zhu)动(dong)拉闸断电,⭕保证用电宁静;
² 总功ꦅ(gong)率限定(ding):电(dian)能表可完成总功(gong)率限定(ding),当(dang)负(fu)荷(he)跨越设定(ding)的最大功(gong)率阀值(zhi)时,电(dian)表主动跳闸(zha),保证用电(dღian)宁静;
² 保(bao)电(dian)(dian)(dian)功(gong)效:电(dian)(dian)(dian)能表(biao)具备保(bao)电(dian)(dian)(dian)功(gong)效,当保(bao🔯)电(dian)(dian)(dian)功(gong)效启(qi)用后,不管何(he)种情(qing)况下电(dian)(dian)(dian)表(biao)都不会跳(tiao)闸(zha)断(duan)电(dian)(dian)(dian),供特别办理情(qing)况下利用;
计量 | 有功电能精确度品级 | A级、B级 | |
丈量 | 电压 | 丈量规模 | 0.6Unom~1.2Unom |
电流 | 丈量规模 | Imin~1.2Imax | |
功率 | 丈量规模 | PQ(起动功率)~1.2Unom×1.2Imax | |
通讯 | 通讯接口 | 红外、RS485 | |
通讯规约 | DL/T 645-1997 | ||
通讯速度 | 1200bps | ||
电气 机能 | 介电强度 | 交换工频电压 | 3kV |
脉冲电压 | 6kV 1.2/50us | ||
电磁兼容 | 疾速瞬变群脉冲 | 实验品级:4级(GB/T 17626.4) | |
浪涌 | 实验品级:4级(GB/T 17626.5) | ||
静电 | 实验品级:4级(GB/T 17626.2) | ||
零件功耗 | ≤0.3W | ||
利用 情况 | 任务温度 | -25℃~+60℃ | |
极限任务温度 | -40℃~+70℃ | ||
绝对湿度 | ≤85%(极限湿度:≤95%) | ||
规格 | 0.25-0.5(30)A、0.25-0.5(60)A、0.5-1(80)A A级 | ||
0.2-0.5(30)A、0.2-0.5(60)A、0.4-1(80)A B级 |